HomeMy WebLinkAbout34-2110-035-0040n I a ~ ~j FtUtKAL tMtKUhM;T MANAUhMtN 1 AUhNUY 6040 U NATIONAL FLOOD INSURANCE PROGRAM
ELEVATION CERTIFICATE
Read the instructions on pages 1- 7.
O.M.B. No. 3067-0077
Expires July 31, 2002
SECTION A - PROPERTY OWNER INFORMATION For Insurance Company Use:
BUILDING OWNER'S NAME Policy Number
Dorouth Moncur
BUILDING STREET ADDRESS (Including Apt., Unit, Suite, and/or Bldg. No.) OR P.O. ROUTE AND BOX NO. Company NAIC Number
1801 N.W. 171" Street
CITY STATE ZIP CODE
MIAMI, MIAMI-DADE COUNTY FL 33056
PROPERTY DESCRIPTION (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
Lot 4, Block 12 " Sunny Lakes Estates" PB 95, Pg 6 Miami - Dade County Records
BUILDING USE (e.g., Residential, Non-residential, Addition, Accessory, eta Use a Comments area, if necessary.)
Residential
LATITUDE/LONGITUDE (OPTIONAL) HORIZONTAL DATUM: SOURCE: ❑ GPS (Type):
( - - or ##.#a) ❑ NAD 1927 ❑ NAD 1983 ❑ USGS Quad Map ❑ Other.
SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
B1. NFIP COMMUNITY NAME & COMMUNITY NUMBER 1 $2. COUNTY NAME B3. STATE
UNICORPORATE`D 106x5 - - MIAMf-0ADE
B4. MAP AND PANEL
B5. SUFFIX
87. FIRM PANEL
B9. BASE FLOOD ELEVATION(S)
NUMBER
B6. FIRM INDEX DATE
EFFECTIVEIREVISED DATE
B8. FLOOD ZONE(S)
(Zone A0, use depth of W N)
1202500080
1
7-17-95
3-2-94
AE
7.0
B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in B9.
❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other (Describe):
B11. Indicate the elevation datum used for the BFE in B9: ® NGVD 1929 ❑ NAVD 1988 ❑ Other (Describe): _
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ® No Designation Date
SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ® Finished Construction
*A new Elevation Certificate will be required when oonshdon of the building is complete.
C2. Building Diagram Number 1(Select the building diagram most similar to the building for which this certificate is being completed - see pages 6 and 7. If no diagram
accurately represents the building, provide a sketch or photograph.)
C3. Elevations - Zones Al A30, AE, AH, A (with BFE), VE, V1-V30, V (with BFE), AR, AR/A, AR/AE, ARIA1 A30, AR/AH, AR/AO
Complete ftems C3.-a4 below according to the building diagram specified in Rem C2. State the datum used. If the datum is different from the datum used for the BFE in
Section B, convert fire datum to that used for the BFE. Show field measurements and datum conversion calculation. Use the space provided or the Comments area of
Section D or Section G, as appropriate, to document the datum conversion.
Datum NGVD-29 ConversiolvComments _
Elevation reference mark used DC BM Does the elevation reference mark used appearon the FIRM? ❑ Yes ®No
❑ a) Top of bottom floor (including basement or enclosure) 7. 84 ft.(m)
❑ b) Top of next higher floor N/A. _ft.(m) U)
❑ c) Bottom of b &%l horizontal structural member (V zones only) N/A. _ft.(m) o
d) Attached garage (top of slab) - 7. -0a tt(m} 0
C3 e) Lowest elevation of machinery ardor equipment w
servicingthebuilding(( A/C Compressor Pad) 7.3ft.(m) E
❑ f) Lowest adjacent (finished) grade (LAG) 6.6 fL(m) Z
❑ g) Highest adjacent (finished) grade (HAG) 6. 8 ft(m)
❑ h) No. of permanent openings (flood vents) within 1 ft. above adjacent grade WA S
J
❑ i) Total area of all permanent openings (flood vents) in C3.h NIA sq. in. (sq. cm)
SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information.
I certify that the information in Sections A, 8, and C on this certificate represents my best efforts to interpret the data available.
I understand that any false statement may be punishable by fine or imprisonment under 18 U. S. Code, Section 1001.
CERTIFIERS NAME NESTOR G RODRIGUEZ LICENSE NUMBER 4277
I I I Lt COMPANY NAME
REGIStERE URV OR PENINSULA LAND SURVEYOR, INC.
ADDRESS CITY STATE ZIP CODE
13113 2 N OPA-LOCKA FL 33054
SIGNATURE DATE TELEPHONE
---7 10-08-01 (305) 687-9191
FEMA Fornt8l-31, JUL 00 AVERSE SIDE FOR CONTINUATION REPLACES ALL PREVIOUS EDITIONS
IMPORTANT: In these spaces, copy the corresponding information from Secd
n A
For Insuranoe Company Use:
BUILDING STREET ADDRESS (Including Apt, Unit, Suite, andlor Bldg. No.) OR P.O. ROUTE AND BOX
1801 N.W. 171 Street
0.
PoLy Number
CRY STATE
MIAMI, MIAMI-0ADE FL
ZIP CODE
33056
Company NAIC Number
SECTION D - SURVEYOR, ENGINEER, OR ARC
ITECT CERTIFICATION (CONTINUED)
Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/comp
ny, and (3) building owner.
COMMENTS
M 0\1_ r%A nC: /'n1 IArTV Dr:klt' J hi A DI! .
❑ Check here if attachments
SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE)
For Zone AO and Zone A (without BFE), complete Items E1 through E4. If the Elevation Certificate is intended for use as supporting informafion for a LOMA or LOMR-F,
Section C must be completed.
E1. Building Diagram Number _(Select the building diagram most similar to the building for which his certificate is being completed - see pages 6 and 7. If no diagram aoanately
represents the building, vide a sketch or E2. The top of the bottom floor (including basement for enclosure) of the building is _ R(m) _ih.(an) L j above or ❑ below (check one) the highest adjacent grade. (Use
natural grade, if available).
E3. For Building Diagrams 6.8 with openings (seepage 7), the next higher floor or elevated floor (elevation b) of the building is _ ft.(m) _in.(crm) above the highest adjacent
grade. Complete items C3.h and C3.i on front of form.
E4. For Zone AO only: If no flood depth number is avaiWe, is the top of the bottom door elevated hn accordance with the conymnity's floodplan management ordinance?
❑ Yes ❑ No ❑ Unknown. The local official must certify this infamation in Section G.
SECTION F - PROPERTY OWNER (OR OWNER'$ REPRESENTATIVE) CERTIFICATION
The property owner or owner's authorized representative who completes Sections A, 0, C (Items C3.h and C3.i only), andE for Zane A (without a FEMA4ssued or community-
issued BFE) or Zone AO must sign here. The statements in Sections A, B, C, and E are correct to the best of my knowledge.
OWNER'S OR OWNER'S AUTHORIZED REPRESENTATIVE'S
STATE ZIP
TE
COMMENTS
TELEPHONE
❑ Coleco here if attachments
SECTION G - COMMUNMYY INFO TION (OPTIONAL)
The kx;d, official who is authorized by law or ordinance to administer the communitys flopdplain m4nagernent ordinance can complete Sections A, B, C (a E), and G of this Elevation
Certificate. Complete the applicable item(s) and sign below.
G1. ❑ information to Section C was taken ftm-ottv docurnentatiort &I has been certify won unorrnation. (Ind source and c late ee~ v,and embossed by a fro~rrsad surveyor, erxj, or an~riecf who is authorized by
state or local law Comments area blow.)
G2. ❑ A own* official completed Section E for a building located in Zone A (without a FEMAAssued or community-issued BFE) or Zone A0.
G3. ❑ The following information (items G4-G9) is provided fa community floodplain mairnageme j purposes.
G4. PERMIT NUMBER G5. DATE PERMIT ISSUED G6. DATE CERTIFICATE OF CONPLIANCEIOCCUPANCY ISSUED
G7. This permit has been issued for. ❑ New Construction ❑ Substantial Improvement
G8. Elevation of as-built lowest floor (including basement) of the building is: - _ft.(m) Datum:
G9. BFE or (in Zane AO) depth of flooding at the buiding site is: l _ ft.(m) Datum:
LOCAL OFFICIAL'S NAME j TITLE
COMMUNITY NAME TELEPHONE
SIGNATURE DATE
Check here if attachments